Wagner Twin Control
Key Features:
- No reworks or rejects due to off-ratio spraying
- No mixed material left unused. Mix only what is required
- Reduction in time for manual cleaning and mixing
- procedures
- Increase in productivity
- Substantial reduction in paint waste and solvent
- consumption
- Reduced maintenance
- Material consumption monitoring
Description
For more information please click here to see the product on our Elmbridge UK website
With the TwinControl, Wagner offers a unique entry solution for 2K applications. The portable TwinControl is an economical, compact and easy-to-use system for a wide range of demands, including high viscosity material applications and high delivery rates.
The external magnetic stroke meter is an effective alternative to gear flow meters and allows mixing ratios up to 20:1 with a high ± 2 % precision. As a result, TwinControl is the perfect solution to mixing and applying 2K materials in the wood and metal industries, especially for protective coating requirements.
Additional Information
User-Friendly
TwinControl will show you how easy it is to handle 2K materials. Connect the unit, set the main parameters, push the start button – and start working!
High Reliability
TwinControl is perfect even for critical applications such as abrasive materials, reactive paints, high viscosity materials and high delivery rates. The special software prevents off-ratio spraying and controls all working parameters to ensure a consistent and precise mixing quality.
Main Functions
- Real time mixing control with off-ratio alarm
- Pot-life monitoring with alarm
- Automatic flushing process
- Real time delivery rate display
- Mixing accuracy display
- Material consumption monitoring
- Pump diagnosis system: pre-alarm and alarm in case of pump malfunction
- Gun Flush Box connection optional
- All the working parameters can be set directly on the control panel. A 3-level password prevents unauthorized personnel from monitoring sensitive data
Pump A | 18 – 40 | 28 – 40 | 35 – 70 | 35 – 150 | 48 -110 |
Pump B | 18 – 40 | 28 – 40 | 35 – 70 | 35 – 70 | 48 – 110 |
Mixing Ratio | 0.1:1 – 20:1 | ||||
Max Working Pressure | 144 Bar | 224 Bar | 250 Bar | 270 Bar | 370 Bar |
Flow Rate at 1:1 Mix Ratio | 2.4L / Min | 2.4L / Min | 4.2 L / Min | 6.6L /Min | 6.6L / Min |
Flow Rate at 4:1 Mix Ratio | 1.5L / Min | 1.5L / Min | 2.6 L / Min | 5.0L / Min | 4.1L / Min |
Flow Rate at 10:1 Mix Ratio | 1.3L / Min | 1.3L / Min | 2.3 L / Min | 4.7L / Min | 3.6L / Min |
Flow Rate at 20:1 Mix Ratio | 1.2L / Min | 1.2L / Min | 2.2 / Min | 4.6L /Min | 3.4b L/Min |
Pump A | 75 – 150 | 72 – 300 | 72 – 300 |
Pump B | 75 – 150 | 75 – 150 | 72 – 300 |
Mixing Ratio | 0:1:1 – 10:1 | ||
Max Working Pressure | 530 Bar | ||
Flow Rate at 1:1 Mix Ratio | 9.0L / Min | 13.5L/Min | 18:1L / Min |
Flow Rate at 4:1 Mix Ratio | 5.6L / Min | 10.1L / Min | 9.5L / Min |
Flow Rate at 10:1 Mix Ratio | 4.9L / Min | 9.5L / Min | 11.2L / Min |
Additional information
Weight | 21669 kg |
---|---|
Brand | Wagner |
Options | 48:110 Turbine |
Weight | |
Type | 35:70 Stand Mount, 48:110 Stand Cart, 48:110 Turbine |